This spring is the most quality one. KZP “Šćona” has got concession on it and also can take 8 l/s for bottle.

Goal of the company is to export bottled water out of Bosnia & Herzegovina.

Požarna - spring capacity: 110 l/s about

 

Type of Watery Building

Capping spring

Title of Watery Building

Municipality

FOJNICA

 

Physical and Chemical Analyses of the Water

 

Analyze Category

 

Unit

Estimated Value

MDK

Water temperature
° C
Color
No
No
No
Aroma
No
No
No
Taste
No
No
No
Stir
NTU
1,00
2,4
pH
7,70
6,5-8,5
Suspended Hard Substances
mg/l
0.00
No
Total Evaporation Remains at 105° C
mg/l
159
Conduction
µS/cm
161
600
TDS (total dissolve substance)
mg/l
80
Total Hardness
mg CaCO3 /l
86
Carbonate Hardness
mg CaCO3 /l
83
Noncarbonate Hardness
mg CaCO3 /l
2
Calcium (Ca)
mg/l
28,0
200
Magnesium (Mg)
mg/l
2,0
50
Natrium (Na)
mg/l
0,70
200
Potassium (K)
mg/l
0,15
12,0
Iron (Fe)
mg/l
0,002
0,30
Manganese (Mn)
mg/l
0,000
0,050
Chloride
mg/l
4,9
200
Sulfate
mg/l
1,5
200
Phosphate
mg/l
0,005
0,15
AMON. Nitrogen
mg N/l
0,02
0,10
Nitrate Nitrogen
mg N/l
0,62
10,0
Nitrate Nitrogen
mg N/l
0,000
0,005
Consumption KMnO4
mg/l
1,20
12,0
Hydro carbonate
mg/l
110
Total mineralization
148,5

According the physical and chemical analyses of the water, specimen of the water is SUITABLE to standard scale of hygienic soundness drinking water.

 

 

 

 

Statement from investment program of bottled water in Fojnica